Request a quote ›
Materials/Sandwich panels

Cladding and thermal envelope

Sandwich panels.

One system combines the outer sheet, insulation core and internal finish. We select the right panel for thermal and fire requirements, hygiene, acoustics, environment and how the building will be used.

Wall and roof sandwich panels with insulating core

Illustrative panel build-up. The exact joint geometry and finish depend on the selected manufacturer and system.

LocationWall and roof
Insulation corePIR / PUR / mineral wool
JointExposed or concealed
AssemblyVertically and horizontally

How the panel works

Three layers. One functional envelope.

Steel cover plates transfer surface stress and protect the core. Insulation limits heat loss and the shaped lock joins adjacent panels to form a continuous perimeter or roof plane.

Sandwich panel composition

Outer sheet / insulating core / inner sheet. Thickness and coating are determined according to the project.

The panel is not just the color of the facade.

During the design, we monitor the thermal requirements, fire resistance, gap between the supports, wind and snow, condensation, internal humidity and the cleaning method.

  • The outer side resists weather, UV radiation and mechanical stress.
  • The core mainly determines the thermal insulation, weight and fire properties of the system.
  • We select the internal finish for the operation: workshop, warehouse, food production, vehicle wash or offices.
  • Junctions, plinths, parapets, corners and penetrations are just as important for weather-tightness as the panel itself.

Core types and systems

Different buildings. Different priorities.

There is no one universally best panel. The combination of price, thermal protection, fire, acoustics, hygiene and service life in a particular environment is decisive.

01 / PIR

PIR wall panel

Very good thermal performance with less thickness. A frequent choice for heated halls, workshops, warehouses and administrative inserts.

02 / PUR

PUR panel

Light cladding with good thermal insulation. Availability and exact parameters depend on the manufacturer's product line.

03 / MW

Mineral wool

Higher weight, good acoustic properties and solutions for increased fire requirements. The choice is confirmed by the fire project.

04 / ROOF

Roof panel

The profiled top plate drains water and transfers the load. The slope of the roof, sealing, anchoring and ridge solution are important.

05 / AGRO

Agricultural-grade panel

Internal surface and joint adapted to humidity, ammonia and regular washing. The specific exposure of the operation is assessed.

06 / HYGIENE

Hygienic and cold-storage panels

Smoother surfaces, sealed details and reduction of thermal bridges for the food industry, cold stores and regulated areas.

Indicative comparison

What determines the build-up.

We do not choose the thickness based only on whether the object is "insulated". The required internal temperature, the size of the object, airtightness, technology and local climatic conditions are decisive.

SystemCommon range of thicknessesA strong pointTypical useNeed to check
PIR / PUR wallapproximately 40–200 mmThermal performance and low weightHalls, workshops, warehouses, service facilitiesFire, temperature, span, type of joint
Mineral woolapproximately 60–240 mmFire and acoustic solutionsProduction, fire separation structures, noisy operationsWeight, anchoring, designed resistance
Roof panelapproximately 60–200 mmInsulation and covering in one elementHalls, warehouses, extensions, workshopsSnow, wind, slope, transitions, drainage
Refrigeration / hygienicaccording to the temperature regimeTightness and cleanable surfaceFood industry, refrigeration, washable operationsVapor tightness, details, doors and transitions
Important

The ranges are indicative. The final thickness, load-bearing capacity, fire classification and method of anchoring are confirmed by a specific technical sheet, statics, thermal engineering assessment and fire project.

Connections and anchoring

The detail that decides the result.

With an exposed joint, the fastener remains visible. A concealed joint hides it beneath the next panel for a cleaner facade. Both systems require correct sealing, fastener spacing and connection to the supporting structure.

Illustrative comparison of the exposed and hidden joint of sandwich panels

Illustrative exposed joint on the left and concealed fixing on the right. The actual joint profile varies by system.

Key installation details

  • Type and number of self-drilling screws according to the substrate, wind and manufacturer's recommendation.
  • EPDM sealing pads, or calots for roof cladding.
  • Sealing tapes and sealants at joints, plinths, parapets and around penetrations.
  • Minimization of thermal bridges and continuity of the vapor barrier layer.
  • Dilation, tolerances of the steel structure and the direction of laying the panels.

Appearance of the facade

Profiling changes the visual scale of the building.

The same hall can appear technical, elegant or utilitarian depending on panel orientation, module width, profiling and the contrast of the flashings.

Four visual versions of the facade made of sandwich panels

Illustrative variants: horizontal micro-profile, vertical laying, bright smoother surface and more pronounced profiling.

Common design options

Manufacturers offer a fine micro-profile, linear grooves, smoother surfaces and more pronounced profiles. Availability depends on the specific panel, sheet thickness, color and production series.

Micro profileLinear profileSmooth designWavy profileHorizontal mountingVertical mounting
  • Dark shades will accentuate unevenness and thermal expansion more.
  • The combination of directions and colors must respect the module of the panel and the supporting structure.
  • We approve the exact shade according to the physical sample, not just the screen.

Complete system

The panel is only the beginning.

All terminations and transitions are part of the functional casing. KESALOP designs, manufactures or provides them as one coordinated unit.

01

Plinth

Connection to the base plate, waterproofing and terrain without open insulation.

02

Corners and parapets

External and internal corners, facade terminations and cover flashings.

03

The roof

Ridge, gutter, gable edges, gutters, downspouts and safe passages.

04

Openings

Linings of windows, doors and industrial gates with water drainage and sealing.

05

Technologies

Ventilation, wiring, fire elements and transitions coordinated with cladding.

Related chapters

Complete every detail.

We select the panel together with the load-bearing structure, flashings and final colour scheme of the building.

We design the entire envelope of the building.

From the panel type and load-bearing structure to flashings, gates and the building interior.

Phone+421 944 385 605
E-mailobjednavky@kesalop.sk